Permit: T05BU00955

Parcel: 128100550


Addresses:

250 S WILLIAMS BL


Inspection Status: Approved

Inspection History: STORMWATER FOLLOW-UP INSP

Permit Number - T05BU00955

Inspection Description - STORMWATER FOLLOW-UP INSP

Inspection Status - Approved

Date Description Inspector Results Comments
09/18/2006 STORMWATER FOLLOW-UP INSP Approved
06/12/2006 STORMWATER FOLLOW-UP INSP Partial Approval SIDEWALKS AND RAMPS BEING INSTALLED-CALLED ROW INSPECTOR NICK AND ADVISED
SILT FENCE IN NEED OF REPAIRS ALONG THE N AND W SIDES OF PROJECT
06/01/2006 STORMWATER FOLLOW-UP INSP Correction Required SIDEWALK BEING INSTALLED
DRIVEWAY APPROACHES BEING FORMED UP

1 RE-ESTABLISH SEDIMENT CONTROLS ALONG N/NE SIDE OF PROJECT
2 RE-ESTABLISH ROCK IN CONSTRUCTION ENTRANCES
3 PROTECT STORMDRAIN INLET S OF SOUTHERN CONSTRUCTION ENTRANCE
4 RE-ESTABLISH SEDIMENT CONTROLS ALONG EAST SIDE OF 5 PROJECT AND SOUTH OF SOUTHERN CONSTRUCTION ENTRANCE
6 CONTINUE TO MAINTAIN CONCRETE WASH OUT
05/11/2006 STORMWATER FOLLOW-UP INSP Correction Required 1 RE-ESTABLISH SEDIMENT CONTROLS ALONG N/NE SIDE OF PROJECT
2 RE-ESTABLISH ROCK IN CONSTRUCTION ENTRANCES
3 PROTECT STORMDRAIN INLET S OF SOUTHERN CONSTRUCTION ENTRANCE
4 RE-ESTABLISH SEDIMENT CONTROLS ALONG EAST SIDE OF 5 PROJECT AND SOUTH OF SOUTHERN CONSTRUCTION ENTRANCE
6 CONTINUE TO MAINTAIN CONCRETE WASH OUT
04/03/2006 STORMWATER FOLLOW-UP INSP Correction Required SIGN, BERM AND USE CONCRETE WASH OUT (NOT ON SITE 3RD NOTICE)
PROTECT STORM DRAIN INLET SOUTH OF PROJECT (NOT DONE)
SWEEP WILLIAMS CIR AT SOUTH CONSTRUCTION ENTRANCE
03/29/2006 STORMWATER FOLLOW-UP INSP Correction Required SIGN, BERM AND USE CONCRETE WASH OUT
PROTECT STORM DRAIN INLET SOUTH OF PROJECT
SWEEP WILLIAMS CIR AT SOUTH CONSTRUCTION ENTRANCE
03/22/2006 STORMWATER FOLLOW-UP INSP Correction Required ONSITE WITH BEV
CONCRETE WASH OUT NEEDS TO BE PLACED AND SIGNED ON SITE
REMOVE AND DISPOSE OF CONCRETE DEBRIS
SWPPP AND NOI/AZPDES NEEDS TO BE POSTED W/ GRADING PERMIT
03/15/2006 STORMWATER FOLLOW-UP INSP Correction Required RE ESTABLISH ALL SWPPP CONTROLS
-GRAVEL FILTER BAGS @ STORMDRAIN INLETS (NOT DONE 2ND NOTICE)
-SILT FENCE IN PLACE AND IN GOOD WORKING ORDER-OK
-ROCK IN STABILIZED CONSTRUCTION ENTRANCES-LITTLE TRACK OUT FROM SITE OK FOR NOW
POST GRADING PERMIT, NOI, AZPDES AND SWPPP ON SITE-IN JOB TRAILER NOT POSTED
03/06/2006 STORMWATER FOLLOW-UP INSP Correction Required RE ESTABLISH ALL SWPPP CONTROLS
-GRAVEL FILTER BAGS @ STORMDRAIN INLETS
-SILT FENCE IN PLACE AND IN GOOD WORKING ORDER
-ROCK IN STABILIZED CONSTRUCTION ENTRANCES
POST GRADING PERMIT, NOI, AZPDES AND SWPPP ON SITE
09/23/2005 STORMWATER FOLLOW-UP INSP Partial Approval NO CONCERNS AT THIS TIME.
08/15/2005 STORMWATER FOLLOW-UP INSP Partial Approval THE SITE WAS CHECKED TO ENSURE THAT THE PREVIOUS COMMENTS HAVE BEEN ADDRESSED. THE DEVELOPER WILL CONTINUE TO MONITOR THE SITE TO ENSURE THAT ALL OF THE TRACKING IS ADDRESSED AS NEEDED, AND THAT THE CONTROLS ARE MAINTAINED.