Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/31/2006 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* 1) SVRS S/N #014441 |
|
| 01/27/2006 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio |
|
| 01/06/2006 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO CHANGE FROM PRIOR INSPECTIONS-NOTIFIED JERRY |
|
| 11/10/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. POOL PLAN WAS APPROVED IN ERROR. POOL PERMITS APPROVED AFTER APRIL 12, 2005 MUST HAVE 4' BARRIER BETWEEN HOUSE AND POOL - HAVE SITE PLAN REVISED AND COMPLY. 2. POOL SVRS VALVE NOT INSTALLED - STOPPED INSPECTION |
|
| 11/08/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BARRIER REQUIREMENTS NOT MET: WINDOWS OPENING TOWARD POOL AREA-CANNOT OPEN MORE THAN 4", CLEARANCE UNDER WEST GATE TO LARGE AND STATIONARY SIDE OF DBL GATE ON EAST END MUST BE SECURED 2) SECURE ELECTRICAL WHIP AT PUMP MOTRO 3) SVRS REQUIRED 4) DRAIN COVERS MUST BE ON SITE 5) STOPPED INSPECTION |
|
| 08/23/2005 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* |