Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/27/2005 |
SHEET ROCK NAILING |
|
Approved |
|
| 04/21/2005 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection :* OK @ WALL |
| 04/20/2005 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection :* 1) SEAL @ PLUM? PENETRATIONS. 2) SEAL @ TOP OF WALL AND ANY OTHER GAPS. 3) ALL ABOVE TO BE FIRE TAPED CALL FOR INSP. BEFORE TEXTURE. |
| 04/19/2005 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection :*OK EXCEPT @ EXTERIOR SOFFIT AREA |
| 04/18/2005 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection :*1) YOU MUST PROVIDE LISTED SYSTEM FOR ALL PENETRATIONS. 2) WHERE SHEET ROCK ON 1ST LAYER HAS A LARGER OPENING FOR PENETRATION THAN 2ND LAYER THEN PULL OFF 2ND LAYER AND ROCK PER USG STANDARDS. 3) SHEET ROOCK ON FIRE WALLS REQUIRES " TIGHT" CONSTRUCTION-USG STATES THAT MEANS 1/8" GAP OR LESS. 4) PLUMBING FOR SINK OUTSIDE OF RESTROOM DOES NOT MEET CODE AND IS NOT SHOWN ON PLAN. 5) ABOVE CEILING NOT NAILED OFF PROPERLY |
| 04/14/2005 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection :* 1ST LAYER |