Permit: T05BU00705

Parcel: 136417210


Addresses:

9941 E LUCILLE DR

Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
04/19/2005 POOL/SPA PRE-GUNITE Approved IVRS - Inspection :*
1) CURRENT CODE INTERPRETATION IS THAT DRAIN COVERS MUST BE 3' APART NOT JUST THE PIPE
04/18/2005 POOL/SPA PRE-GUNITE Partial Approval IVRS - Inspection :*
1) PENDING CORRECTION OF GROUND WIRE CONNECTORS
2) FILTER LINES OK
3) SUPPLY NOT INSTALLED
4) MINIMAL CONDUIT RUN
5) SPLIT BOLTS ARE NOT APPROVED CONNECTORS FOR GROUND WIRE TO REBAR
6) COPPER MUST BE ISOLATED FROM REBAR