Permit: T05BU00686

Parcel: 10406011E


Addresses:

2075 W GARDNER LN


Inspection Status: Approved

Inspection History: STORMWATER FOLLOW-UP INSP

Permit Number - T05BU00686

Inspection Description - STORMWATER FOLLOW-UP INSP

Inspection Status - Approved

Date Description Inspector Results Comments
01/26/2007 STORMWATER FOLLOW-UP INSP Approved SITE IS STABILIZED, ALL PAVING AND PERMANENT STORM WATER CONTROLS IN PLACE. AWAITING FINAL GRADING INSPECTION REQUEST.
12/21/2006 STORMWATER FOLLOW-UP INSP Partial Approval NO SIGNIFICANT CHANGES FROM LAST INSPECTION.
11/20/2006 STORMWATER FOLLOW-UP INSP Partial Approval NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
11/08/2006 STORMWATER FOLLOW-UP INSP Correction Required SWEEP UP TRACKED MATERIAL, PAVING BEING ACCOMPLISHED.
PROVIDE APPROVED REVISION OF ANY SIGNIFICANT CHANGES MADE TO THE APPROVED PLANS.
09/12/2006 STORMWATER FOLLOW-UP INSP Partial Approval NO SIGNIFICANT STORM WATER ISSUES AT THIS TIME - PERIMETER OF SITE IS STABILIZED.

PRIOR TO APPROVAL FROM ENGINEERING FOR A C OF O, COMPLETE THE FOLLOWING:

1) ALL SITE WORK ASSOCIATED WITH THE APPROVED GRADING/SITE PLAN.
2) ALL PARKING, TRASH ENCLOSURES, CURB RAMPS, SIDEWALKS.......
3) PROVIDE A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD STATING THAT THE RET/DET BASIN WAS BUILT IAW THE APPROVED PLANS.
4) A COMPLETED AN APPROVED FINAL GRADING INSPECTION FOR PERMIT # T05BU00686.
07/27/2006 STORMWATER FOLLOW-UP INSP Partial Approval NO STORM WATER CONCERNS AT THIS TIME
07/14/2006 STORMWATER FOLLOW-UP INSP Partial Approval NO STROM WATER CONCERNS AT THIS TIME.
06/14/2006 STORMWATER FOLLOW-UP INSP Partial Approval 1) CALL FOR INSPECTION WHEN SITE IS PAVED/CALL FOR INTERMEDIATE GRADING INSPECTION.
2) PRIOR TO APPROVAL FOR C OF O BY ENGINEERING:
A) COMPLETE SITE WORK PER APPROVED PLAN.
B) PROVIDE A RET/DET BASIN CERTIFICATION STATEMENT BY THE ENGINEER OF RECORD.
C) CALL FOR FINAL GRADING INSPECTION
04/21/2006 STORMWATER FOLLOW-UP INSP Partial Approval NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME.
WORK SOIL IN FRONT OF WALL ALONG EAST SIDE OF SITE AS SOON AS POSSIBLE.
ANY SIGNIFICANT CHANGE TO THE APPROVED GRADING PLAN MUST BE REVIEWED AND APPROVED.
CALL PRIOR TO PROJECT OCCUPANCY DATE SO THAT AN INSPECTION CAN BE ACCOMPLISHED AND ANY PROBLEMS CAN BE ADDRESSED.
02/27/2006 STORMWATER FOLLOW-UP INSP Partial Approval 1) RE-ESTABLISH SEDIMENT CONTROLS (SILT FENCE) ALONG THE WEST BOUNDRY TO PROPERTY - ENSURE BOTTOM OF FENCE IS TIED INTO THE GROUND.
2) DISPOSE OF EXCESS CONCRETE AND MATERIALS PROPERLY, PROVIDE A DESIGNATED CONCRETE WASH OUT AREA.
3) SEDIMENT CONTROLS ARE REQUIRED TO REMAIN IN PLACE UNTIL ALL CURBING IS INSTALLED AND THE SITE IS STABILIZED.
01/12/2006 STORMWATER FOLLOW-UP INSP Partial Approval 1) ENSURE SEDIMENT CONTROLS LOCATED ON THE WEST SIDE OF PROPERTY IS MAINTAINED PERIODICALLY. TRENCH OR KEY IN BOTTOM OF FENCE.
2) ENSURE ROUTINE SEDIMENT CONTROL MAINT INSPECTIONS ARE PRFORMED IN ACCORDANCE WITH YOUR SWPPP.
3) ESTABLISH A DESIGNATED CONCRETE WASH OUT PER YOUR PLAN AND USE IT WHEN NECESSARY.

CALL FOR REINSPECTION IF PROBLEMS OR QUESTIONS ARISE.
12/01/2005 STORMWATER FOLLOW-UP INSP Partial Approval 1) SEDIMENT CONTROLS ARE IN PLACE IN ACCORDANCE WITH THE APPROVED SWPPP.
2) ENSURE PERIODIC MAINT INSPECTIONS ARE PERFORMED AND DOCUMENTED.

NO ADDITIONAL STORM WATER CONCERNS AT THIS TIME.