Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/15/2005 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
| 07/14/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PATIO WALL POOL ENCLOSURE WALL MUST BE AT LEAST 60" HIGH ON SIDE OPPOSITE POOL 2) ENCLOSURE GATES MUST BE SELF CLOSING AND LATCHING. DUEL PANEL GATES MUST HAVE ONE PANLE PHYSICALLY SECURED 3) BOTH PANELS OF FRENCH DOORS MUST BE SELF CLOSING AND LATCHING |
|
| 07/13/2005 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* 1) NO ADULTS AT HOME, PER YOUNG PERSON AT FRONT DOOR |
|
| 07/08/2005 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* 1) NEED SRVS DEVICE 2) EXT. WALLS NOT 5' IN HT., DBL WALL AT REAR NOT 5' 3) HOSE BIB ANTI-SIPHON 4) PERMIT OBTAINED PRE/BARRIER ORDINANCE 5) REINSPECTION FEE DUE |
|
| 05/27/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* |