Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T05BU00565
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/21/2005 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
04/15/2005 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* DIG COLUMN FTGS 24" SQUARE AND 12"N DEEP FROM GROUND LEVEL. PUT 3 #4 REBAR IN THESE. REMOVE ALL LOOSE ROCKS AND CUT GRADE SO YOU HAVE A 4" SLAB |
|
04/13/2005 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :*NOT READY NO BLUEPRINTS ON SITE CALL AGAIN. |