Permit: T05BU00546

Parcel: 141302650

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Permit Number - T05BU00546

Inspection Description - POOL/SPA FINAL/BARRIER

Inspection Status - Approved

Date Description Inspector Results Comments
05/04/2005 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
1) POOL CONTRACTOR IS GOING TO INSTALL 12" X 12" POOL COVERS
05/02/2005 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :* OK WERE HALF WAY THERE, I NEED PUMP INFORMATION PUMP NOT TO EXCEED POOL DRAIN ??. COVERS ARE RATED AT 76 GPM, WHAT IS THE PUMP (GPM?)
04/25/2005 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :*
1) PAPERWORK LEFT ON PLAN TUB WAS A PROPOSAL ONLY WASN'T APPROVED BY CITY COUNCIL
2) 12" X 12" POOL GRATES ARE A GENERIC FIX COVERS CAN BE SIZE PER PUMP DELIVERY AG106 IS A TWO PART REQUIREMENT DRAIN COVERS AND ANTI SUCTION DEVICE
04/22/2005 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :*
1) DOGS LOOSE IN YARD
04/21/2005 POOL/SPA FINAL/BARRIER Partial Approval IVRS - Inspection :*
1) BOND METAL BARRIER
2) LEAVE 12" X 12" DRAIN COVERS ON JOB FOR NEXT INSPECTION 3) MAX 2" CLEAR UNDER METAL BARRIER TO EARTH
3) CODE REQUIRED SEPERATION OF 3' FROM COVER TO COVER NOT PIPE TO PIPE. NEXT POOL PLUMB MAIN DRAINS AT 4'-0"