05/04/2005 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* 1) POOL CONTRACTOR IS GOING TO INSTALL 12" X 12" POOL COVERS |
|
05/02/2005 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* OK WERE HALF WAY THERE, I NEED PUMP INFORMATION PUMP NOT TO EXCEED POOL DRAIN ??. COVERS ARE RATED AT 76 GPM, WHAT IS THE PUMP (GPM?) | |
04/25/2005 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* 1) PAPERWORK LEFT ON PLAN TUB WAS A PROPOSAL ONLY WASN'T APPROVED BY CITY COUNCIL 2) 12" X 12" POOL GRATES ARE A GENERIC FIX COVERS CAN BE SIZE PER PUMP DELIVERY AG106 IS A TWO PART REQUIREMENT DRAIN COVERS AND ANTI SUCTION DEVICE |
|
04/22/2005 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* 1) DOGS LOOSE IN YARD |
|
04/21/2005 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection :* 1) BOND METAL BARRIER 2) LEAVE 12" X 12" DRAIN COVERS ON JOB FOR NEXT INSPECTION 3) MAX 2" CLEAR UNDER METAL BARRIER TO EARTH 3) CODE REQUIRED SEPERATION OF 3' FROM COVER TO COVER NOT PIPE TO PIPE. NEXT POOL PLUMB MAIN DRAINS AT 4'-0" |