Permit: T05BU00482

Parcel: 134232080


Addresses:

6651 E LEHIGH DR

Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
04/07/2005 POOL/SPA PRE-GUNITE Approved IVRS - Inspection :*
04/06/2005 POOL/SPA PRE-GUNITE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAINTAIN MINIMUM 3" CLEARANCE REBAR TO DIRT
2) HORIZONTAL VERTICAL REBAR SPACING NOT PER PLAN
3) DUAL SECTION INTLETS APPEAR TO CLOSE (BOTTOM OF POOL)
4) WILL NEED 36" BETWEEN COVERS ONCE INSTALLED (NEED MANUFACTURER SPECS ON SAME)
5) NEED DRAWINGS INDICATING TYPE, SIZE, INSTALLATION REQUIREMENTS ON SAFETY VACCUM RELEASE SYSTEM