Permit: T05BU00382

Parcel: 125122050

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
09/28/2005 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
09/16/2005 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL GATES LEADING TO POOL AREA MUST SWING IN DIRECTION OPPOSITE THE POOL
2) DOUBLE GATE HEADING TO POOL AREA AT PORCH MUST HAVE 1 GATE PERMANENTLY ANCHORED TO CONCRETE
3) BOND METAL ENCLOSURE
4) DRAIN COVERS TO BE USED MUST BE ON SITE
5) APPROVED DRAWING NEEDED FOR ENCLOSURE INSTALLED
08/30/2005 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE UNUSED CONDUIT WITH WIRE STICKING OUT NORTH EAST CORNER PATIO WALL - HAZARDOUS
2) REMOVE PIPE SAME LOCATION - OUTSIDE WALL - MAY
3) BE USED AS LADDER, STEPPING AREA TO CLIMB WALL
4) SUCTION INLET COVERS BOTTOM OF POD TO BE MIN 36" APART COVER TO COVER (EDGES)
5) DBL GATE FIXED SIDE TO BE PERMANENTLY ANCHORED TO CONCRETE (WELD VERT MOVABLE ROD IN PLACE) (2 GATES)
6) BOND METAL FENCE LESS THAN 5' FROM H2O'S EDGE
7) MUST SHOW ON APPROVED PLANS WHAT IS TO BE USED AS BARRIER AND ENCLOSURE
8) STOPPED INSPECTION