Permit: T05BU00336

Parcel: 141172390

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
05/19/2005 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
1) WATER WAY DRAIN XCOVERS STAMPED ASME APPROVED 95 GPM, BUT SPEC SHEET FROM FACTORY LISTING THEM AT 116 GPM. TOTAL GPM ON SYSTEM APPROX 93 GPM
05/16/2005 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :*
1) NO PLAN TUBE ON SITE
2) NEED POOL MAIN DRAIN COVERS, STAMPED WITH ASME G.P.M., LEAVE PUMP G.P.M. INFORMATION, PUMP NOT TO EXCEED A SINGLE DRAIN COVER
05/13/2005 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :*
1) BOND J-B
2) INSTALL VAC ALERT UNIT
3) NEED ASME APPROVED DRAIN COVERS, G.P.M. NOT TO EXCEED PUMP G.P.M. RATING EA.