Permit: T05BU00267

Parcel: 141130770


Addresses:

9216 E LA PALMA DR

Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
04/21/2005 POOL/SPA PRE-GUNITE Approved IVRS - Inspection :*
04/18/2005 POOL/SPA PRE-GUNITE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE CAUTION TAPE 6" ABOVE ? GAS LINE PER 2003 IRC SECTION 2415.9 AMMENDED
2) YOU MUST PROVIDE 36" SEPERATION FROM INSIDE EDGES OF SECTION INLETS PER 2003 IRC SECTION AG106.4. PLEASE PROVIDE ON SITE THE INLET PIPE TO ANTI VORTEX COVER ADAPTER AND THE ANTI VORTEX COVERS AND THEIR INSTALLATION INSTRUCTIONS AS WELL AS PUMP SUCTION FLOW RATES
3) POOL HEATER MUST HAVE TEMPERATURE AND PRESSURE RELIEF VALVES PER 2003 IRC SECTION M2006.3
4) YOU MUST COMPLY WITH 2003 IRC SECTION AG106 BY FINAL INSPECTION