Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
Permit Number - T05BU00250
Inspection Description - POOL/SPA PRE-GUNITE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/22/2005 | POOL/SPA PRE-GUNITE | Approved | IVRS - Inspection :* | |
03/21/2005 | POOL/SPA PRE-GUNITE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED BOND WIRE FROM PUMP MOTOR TO REBAR CAGE 2) (AUTO FILL) H20 LINE NOT COMPLETED FROM SOURCE TO TIE-IN AT EQUIPMENT-BE SURE TO HAVE TESTABLE TYPE BACKFLOW DEVICE FOR AUTO FILL LINE (WILL INSPECT PRIOR TO FINAL) 3) ELECTRIC NOT RUN TO EQUIPMENT FROM SUB PANEL 4) WILL NEED APPROVED VACCUM RELIEF SYSTEM AT FINAL AT EQUIPMENT PER NEW CODE |