Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05BU00239

Parcel: 141302750

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Permit Number - T05BU00239

Inspection Description - POOL/SPA FINAL/BARRIER

Inspection Status - Approved

Date Description Inspector Results Comments
06/14/2005 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
05/18/2005 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection :*
1) I APPRECIATE THE INFORMATION YOU LEFT IN THE PLAN TUBE. I WANT TO RUN IT BY BY SUPER, HOWEVER FILLING THESE POOLS WITHOUT A FINAL IS NOT A GOOD THING. IF YOU HAVE A PROBLEM LIKE THIS AGAIN MY PHONE NUMBER IS 909-5176. PLEASE LET ME KNOW, I WILL DO WHAT I CAN TO HELP
05/09/2005 POOL/SPA FINAL/BARRIER Partial Approval IVRS - Inspection :*
1) PLAN CALLS FOR POOL (DRAIN COVERS) RATED AT 116. ONES LEFT ON SITE ARE 95 G.P.M.
04/06/2005 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL T & P AT POOL HTR
2) FRONT GATE NOT SELF CLOSING
3) NEED TO COMPLY WITH AG 106 POOL CODE (DRAIN COVERS AND ANTI-ENTRAPMENT DEVICE)
4) USE G.E. BREAKER FOR SUB-PANEL, REMOVE SCREW AND FALSE COVER. COULD NOT GET SCREW OUT