Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2005 | POOL/SPA FINAL/BARRIER | Approved | ||
| 08/24/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTERIOR PERIMETER WALL TO BE 5' HIGH MEASURED FROM OUTSIDE OF WALL 2) NEED ACCESS TO CHECK REAR DOORS TO CODE 3) ALL DOORS TO BE SELF CLOSING AND SELF LATCHING WITH LATCHES AT 54" 4) ONE SIDE OF DBL DOORS TO BE PERMANENTLY ANCHORED SHUT 5) NEED VERIFICATION OF 8005, 9030, 8035 APPROVALS |
|
| 08/22/2005 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | IVRS - Inspection :* 1) NO BARRIER BETWEEN HOUSE AND POOL |
|
| 07/25/2005 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DOG IN YARD 2) NO ACCESS FOR INSPECTION |