Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T05BA00112

Parcel: 12101262G


Addresses:

6001 E PIMA ST


Inspection Status: Basin - Good

Inspection History: COT - BASN - Drainage/Basin - Annual Inspection - Recur

Plan Number - T05BA00112

Inspection Description - COT - BASN - Drainage/Basin - Annual Inspection - Recur

Inspection Status - Basin - Good

Date Description Inspector Results Comments
04/25/2016 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
03/13/2015 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair EROSION ON INLET ON EASTSIDE OF BASIN
12/20/2013 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
06/18/2013 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
01/16/2013 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair BASIN IN FAIR CONDITION
BLEEDER PIPE HALF BLOCKED, EROSION OF SIDE SLOPES, AND UNDERMINING OF ONE PARKING SPACE
06/13/2012 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair BASIN IN FAIR CONDITION. MINOR AMOUNTS OF SEDIMENT AND VEGETATION HAS BEEN NOTED WITHIN THE BASIN LIMITS. A RE-INSPECTION OF THE SITE WILL BE PERFORMED WITHIN THE NEXT 3 MONTHS.
08/23/2010 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair Slope erosion amd debris in basin
08/26/2008 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair slope erosion, plugged outlets and inlets
11/29/2021 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good GOOD
12/24/2020 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good GOOD
01/29/2020 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
02/27/2019 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
04/11/2018 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
06/05/2017 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair MINOR EROSION REPAIR NEEDED AROUND THE BASIN, MINOR TRASH, DEBRIS, AND WEEDS NEED TO BE REMOVED FROM WITHIN THE BASIN.
03/22/2005 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good Pond in good cond. No maintenance needed at this time.
11/29/2022 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
04/09/2024 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair
COT - BASN - Drainage/Basin - Annual Inspection - Recur Scheduled
11/28/2023 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair connecting drainage pipe in basin east of building F 97-116, is no longer draining north as intended (pipe head wall significantly above grade. far west basins need landscaping/clean-up.