Inspection Status: Violation
Inspection History: INITIAL CODE VIOLATION
| Date |
Description |
Inspector |
Results |
Comments |
| 12/06/2004 |
INITIAL CODE VIOLATION |
|
Violation |
ELECTRICAL SHORT/CIRCUIT OVERLOAD IN S.E. BEDROOM, MINOR SCORCHING AND SMOKE BRANCH CIRCUIT REQUIRES REPAIR - PERMIT REQUIRED . OLD HOUSE HAS A 110V DROP TO TWO 30 AMP FUSES. SOMEONE BY-PASSED FUSES ALLOWING CURRENT OVERLOAD - BRANCH CIRCUIT TO BEDROOM (CEILING LIGHT TO RECEPTACLE LEG) REQUIRES REPAIR AND HOME MUST BE PROPERLY FUSED./ BYPASSED FUSES AT 110V 30A DROP ALLOWED MC CABLE IN CEILING TO ARC AND START SMALL ROOF FIRE. PERMITS REQUIRED FOR ELECTRIC REPAIR. |