Inspection History Details
Inspection Status: Violation
Inspection History: INITIAL CODE VIOLATION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2004 | INITIAL CODE VIOLATION | Violation | 1. NEIGHBORHOOD ORD #9816 16-11C - DWELLING UNITS ARE TO HAVE ELECTRICAL FACILITIES MAINTAINED IN A HAZARD FREE STATE AND ALSO IN STATE OF GOOD REPAIR. THE SYSTEM SHALL BE FREE FROM SUCH HAZARDS BARE WIRING, MISUSE OF WIRING, NON APPROVED WIRING, EXPOSED WIRING, BROKEN LOOSE OR FRAYED WIRING. A. EACH STRUCTURE OR APARTMENT SHALL HAVE ONE DISCONNECTING MEANS FOR EACH, NOW A & B FED OFF ONE DISCONNECT. B. EXPOSED CONNECTION ABOVE METERS ON HOT LEGS (EXPOSED HOT WIRES). C. CORRODED TERMINATIONS AT DISCONNECTS BOTH MAIN SWITCH AND HOUSE SWITCH. D. STRANDED WIRING WRAPPED AROUND SCREWS AT DISCONNECTS ARE IMPROPER WIRING. E. CHRISTMAS LIGHTING WRAPPED AROUND SERVICE ENTRANCE CONDUCTORS ABOVE SERVICE. F. MISSING OUTDOOR FIXTURE AT UNIT "B". THE INSIDE OF UNIT "B" SHALL HAVE ALL DEVICES CONNECTED, SMOKE DETECTORS IN BEDROOMS, AND ALL ELECTRICAL WIRING TO BE IN A SAFE MANNER. PLEASE HAVE YOUR LICENSED ELECTRICAL CONTRACTOR OBTAIN A GENERAL REPAIR PERMIT FOR ABOVE ITEMS, MAKE REPAIRS AND CALL FOR INSPECTIONS IN ORDER TO BE REPAIRED. FU FOR 5 DAYS. |