Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/07/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) ALL CORRECTIONS HAVE BEEN MADE | |
| 01/05/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE A ENCLOSURE FOR WATER HTR. 2) SHALL EXTEND T &P DRAIN AND TERMINATE 6" ABOVE BASE WITH NO THREADS @ END OF PIPE, COPPER, CPVC OR GALVANIZED MATERIAL MAY BE USED. 3) SHALL STRAP DOWN GAS LINE ON ROOF WITH APPROVED STRAPS EVERY 6'. 4) GAS PRESSURE TEST IS OK |
|
| 01/04/2005 | PLUMBING - GAS PRESSURE TEST | Cancelled | ||
| 01/04/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 01/03/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : PLEASE HAVE SOMEONE PRESENT TO PROVIDE ACCESS TO ENTIRE GAS SYSTEM AT TIME OF REINSPECTION 9:40AM |