Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/28/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*/1)CORRECTIONS MADE OK 2)OK FOR GAS 3)UCC LEFT AT METER SW GAS 889-1888 |
| 12/23/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/BOND GAS LINE TO WATER LINE 2)SEAL EXTERIOR WALL PENETRATIONS 3)REQUIRE SHUT OFF VALVE AT COLD INLET TO WATER HEATER- NOTE" PVC & CPVC NOT APPROVED IN EXPOSED INTERIOR LOCATIONS 4)REQUIRE 1" CLEARANCE FROM CONBUSTIBLES MATERIAL AT HEATER VENT 5)NO COMBUSTION RELIEF AT WATER HEATER 6)THIS MAY NOT BE A COMPLETE LIST OF VIOLATIONS. YOU MAY WANT TO HIRE A LICENSED CONTRACTOR TO TAKE A LOOK. 7)PRESSURE TEST OK |