Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/27/2004 PLUMBING - GAS PRESSURE TEST Approved
12/20/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/GAS LINE NOT HOLDING PRESSURE. REMOVE THE UNION ON THE GAS LINE FROM THE WATER HEATER. PROVIDE AGA. APPROVED GAS VALVES ON ALL APPLIANCES. SECURE DRAFT DIVERTER TO THE WATER HEATER. PROVIDE MIN 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS