Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2004 | PLUMBING - GAS PRESSURE TEST | Approved | THE ONLY CORRECTION REMAINING WAS THE USE OF A "T" FITTING IN THE GAS LINE FOR FUTURE USE. SPOKE TO DAVE MANN AND WE BOTH AGREE THAT THIS FITTING IS ACCEPTABLE. | |
| 12/22/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/CAN NOT HAVEA FLEX CONNECTOR PENETRATE THE FURNACE HOUSING. THIS MUST BE HARD PIPED THEN CONNECT THE FLEX CONNECTOR 2)SHALL EXTEND FLU VENT 3'0" ABOVE COOLER 3)SHALL REMOVE TEE WITH PLUG @ HOUSE SUPPLY ENTRY 4)BLK PIPE IS NOT APPROVED MATERIAL FOR T&P DRAIN AND CONNOT HAVE THREADS @END OF PIPE TERMINATION 5)RE TEST THE SYSTEM 6)OK TO BACKFILL TRENCH 1)SHALL REMOVE TEE WITH PLUG @ HOUSE SUPPLY ENTRY AS REQUESTED 2)SHALL PAY A REINSPECTION FEE PRIOR TO NEXTA INSPECTION |
|
| 12/21/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/10 PSI PRESSURE TEST SHALL HOLD FOR MINIMUM OF 15 MINUTES |