Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK 2)ALL CORRECTIONS HAVE BEEN MADE | |
| 12/20/2004 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :*/PARTIAL TEST ONLY AT THIS TIME. PLEASE COMPLETE WORK AS PER PETITION OF APPEAL #2004-133 & CALL TO COMPLETE INSP. UNOCCUPIED AT THIS TIME. | |
| 12/20/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL PROVIDE GAS SHUT OFF VALVE @ COOK TOP RANGE 2)SHALL OBTAIN A APPEAL FORM FROM OUR OFFICE FOR ALTERNATE METHOD OF INSTALLATION OF T & P DRAIN AND HAVE THIS APPEAL ON SITE @ TIME OF INSPECTION 3)SHALL REMOVE UNION IN LINE DOWNSTREAM FROM METER AND REPLACE WITH RIGHT & LEFT HAND NIPPLE. 4)RE TEST THE SYSTEM |