Permit: T04PL02196

Parcel: 11307005A


Addresses:

1843 E GLENN ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/21/2004 PLUMBING - FINAL Partial Approval IVRS - Inspection :*/OK ON EXTERIOR PIPING UNDERGROUND, STILL NEED WIRSBO? INSTALLATION INFORMATION FOR USE IN EXPOSED AREAS SUBJECT TO DAMAGE & FREEZING
12/17/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)PROVIDE SUPPORT FOR SHOWER DIVERTOR VALVE. 2)PROVIDE SEPERATION OF HOT & COLD WIRSBO.AQUA PEX 3)PROVIDE INSTALLATION INSTRUCTION FOR WIRSBO AQUA PEX IN EXPOSED AREA THAT ARE SUBJECT TO DAMAGE AND FREEZING 4)PROVIDE CORRECT INSTALLATION AT WATER HEATER OF WIRSBO 5)PLEASE TERMINATE WATER HEATER AT 90 DEGREE DOWN TO AVOID POSSIBLE SCALDING
12/15/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/PLEASE HAVE SOMEONE PRESENT TO PROVIDE ACCESS TO BUILDING ON DAY OF RE-INSPECTION