Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/20/2005 | PLUMBING - FINAL | Approved | IVRS - Inspection :* PLEASE PROVIDE A MECHANICAL PERMIT FOR THE NEW FURNACE. PROVIDE HIGH & LOW COMBUSTION AIR TO FURNACE CLOSET. PROVIDE A DOOR ON FURNACE CLOSET & MAINTAIN MIN 3" CLEARANCE FROM FRONT OF FURNACE. WILL LEAVE GAS CLEARANCE UP ON MECHANICAL FINAL. | |
| 01/19/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NO ONE HOME | |
| 01/14/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SECURE THE DOUBLE WALL VENT PIPE FROM THE FURNACE INSIDE THE 2ND FLOOR CHASE. MAINTAIN MIN. 1" FROM COMBUSTIBLES 2)THE VENT FROM THE WATER HEATER CONNOT TERMINATE UNDER A WINDOW & MUST BE MIN. 8' AWAY FROM THE WALL OR 2' HIGHER THAN UPPER ROOF. 3)GAS PRESSURE TEST IS OK. RECALL FOR INSPECTION |