Permit: T04PL02144

Parcel: 135111230


Addresses:

7538 E 35TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/21/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/CORRECTIONS MADE. GAS CARD AT METER 889-1888
12/15/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)PROVIDE MINIMUM 10 PSI TEST ON ENTIRE SYSTEM AT TIME OF INSPECTION 2)COMPLETE PIPING TO METER AND FURNACE & WATER HEATER 3)PROVIDE GRAVITY DRAIN TO DAYLIGHT FOR WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN 4)PROVIDE CORRECT VENTING FOR FURNACE & WATER HEATER. 5)PROVIDE BONDING OF BUILDING GAS PIPING 6)VENT FROM WATER HEATER & FURNACE TO BE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE