Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/08/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/14 PSI AIR TEST FROM METER LOCATION TO STOVE & WATER HEATER ONLY OK. 1)PROVIDE DIELECTRIC BETWEEN GASV. PIPE & COPPER 2)PROVIDE APPROVED BASE FOR WATER HEATER SEE 94UPC SECTION 510.6 3)CORRECT WATER HEATER T&P DRAIN 4)INSULATE ALL EXPOSED PIPING SUBJECT TO FREEZING. UPON ENTRY INTO HOME NOTICED PROPANE BOTTLE WITH HEATER ATTACHED, WAS TOLD NOT BEING USED FOR BUILDING HEAT, (NO HEATER IN BUILDING) TOLD OCCUPANT THIS WAS VERY UNSAFE CONDITION. |