Permit: T04PL02127

Parcel: 136331560

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/15/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/15 PSI AIR TEST FROM METER TO WATER HEATER & FURNACE OK. CORRECTION MADE. GAS CARD AT METER
12/14/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*16 PSI AIR TEST ON 1" PE UNDERGROUND FROM METER TO BUILDING UP OVERHEAD TO SERVICE ENTRANCE TO WATER HEATER & FURNACE PARTIAL APPROVAL PENDING NOTE #2 AND RE-TEST OF INTERIOR PIPING. 1) PROVIDE AGA OR CSA APPROVED GAS VALUES & FLEXES FOR ALL APPLIANCES. 2) ROUTE GAS PIPING SO WATER HEATER SHALL HAVE ACCESSIBILITY FOR REPLACEMENT. 94 UPC 511.0 3) PLEASE CHECK DOUBLE WALL VENT THRU ATIC SPACE FOR 1"MINIMUN CLEARANCE FROM COMBUSTIBLES. 4) REMOVE TAPE FROM SINGEL TO DOUBLE WALL CONNECTION IN FURNACE AREA.