Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/1)CORRECTIONS MADE OK. 2)OK FOR GAS 3)UCC LEFT AT METER SW GAS 889-1888 | |
| 12/07/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES COUPLINGS SHALL BE USED 2)TERMINATE WATER HEATER TEMPERATURE & PRESSURE RELIEF DOWN 3)INSTALL CORRECT VENT SIZE AT FURNACE AND INSTALL VENT CORRECTLY AT WATER HEATER WITH APPROVED VENT CAP 4)ALL GAS PIPING PENETRATING ROOF SHALL HAVE ROOF FLASHINGS |
|
| 12/06/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) UNABLE TO RETREIVE MESSAGES 9:10 AM PLEASE HAVE SOMEONE PRESENT ON DAY OF CALL IN FOR REINSPECTION |