Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
Permit Number - T04PL02101
Inspection Description - PLUMBING - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* NO ANSWER AT DOOR |
|
11/30/2004 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :*/1)PERMIT IS FOR GAS REPLACE, HOWEVER THE GAS IS ON AND A NEW LINE HAS BEEN RUN TO SHED 2)INSIDE WATER HEATER CLOSET, UNAPPROVED VALVES, DISCONNECTED APPLIANCES WITH OPEN PIPING. OUTSIDE IS A THREAD PROTECTOR INSTEAD OF A UNION. I SPOKE WITH SW GAS. THE PERMIT SHOULD HAVE BEEN FOR A METER RELOCATE. PIPING FOR RELOCATED METER OK. PRESSURE TEST OK. OK TO COVER - CONTRACTOR TO INSURE CLEAN FILL IS USED 6" AROUND PIPE 3)MAKE CORRECTIONS, MAKE FINAL CONNECTIONS AND RECALL FOR INSPECTION. WHERE IS PERMIT FOR NEW WATER HEATER? 5)REINSPECTED - OK FOR GAS UCC LEFT AT METER |