Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/30/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)PROVIDE ROOF FLASHING FOR VENT FROM WATER HEATER 2)PROVIDE DOUBLE WALL VENT TO POINT OF TERMINATION 3)ROOF TOP PIPING TO BE SUPPORTED & SECURED AT CORRECT INTERVALS 4)PROVIDE BONDING OF BUILDING GAS PIPING 5)WATER HEATER TO SIT ON CONCRETE 6)WATER HEATER T&P DRAIN TO BE SOLDERED?. 7)PVC SCH 40 PIPING CANNOT BE USED FOR WATER SUPPLY INSIDE OF BUILDING OR STRUCTURE, AND CANNOT BE IMBEDDED IN CONCRETE 8)WALL HEATER VENT TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE. THIS MAY NOT BE A COMPLETE LIST. |