Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE ON REVISED PLAN. AS PER LAST REQUEST. ALL VERIFICATION OF GRADE HAS BEEN SENT TO RECORDS. WILL NEED CERTIFICATE OF COMPLETION FROM PIMA COUNTY BEFORE FINAL IS GIVEN | |
| 05/02/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* PLEASE NOTE: WILL NEED A REVISION ON VENT AT LIFT STATION ON INSTALL VENT AS PER PLAN. WILL NEED CERTIFICATE OF COMPLETION FROM P.C D.E.Q. AT TIME OF FINAL. VERIFICATION OF GRADE ON JOB AT TIME OF FINAL. PLEASE NOTE: YOUR REVISED PLAN WILL NEED TO GO THRU PLAN CHECK FOR APPROVAL. | |
| 04/29/2005 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 04/06/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* 1) FROM M-H #3 TO LIFT STATION-W/Z=HCS TEST OK SEE NOT 3/15/05 AND 3/16/05 |
|
| 03/17/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* MAN? TEST FROM M-H #1 TO MH #2 TO MH #3 & TO PRIVATE LIFT STATION TEST OK NEED PRESSURE TEST FROM M-H #3 TO LIFT STATION. | |
| 03/16/2005 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* PLEASE SEE DETAIL ON LIFT STATION FOR SIZE OF VENT PLAN CALLS FOR 4"VENT 3" HAS BEEN INSTALLED & REDUCED TO 2" WITH FILTER ?. PLEASE PROVIDE AN APPROVED REVISED PLAN OR INSTALL AS PER APPROVED PLAN. | |
| 03/15/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* PLEASE NOTE WILL NEED VERIFICATION OF GRADE ON SITE SEWER ALSO CERTIFICATE OF COMPLETION FROM PIMA COUNTY ENVIRONMENTAL QUALITY AT TIME OF FINAL. FROM M-H # 3 TO M-H #2. TEST OK. 3" PRESSURE SEWER FROM LIFT STATION TO DISCHARGE MANHOLE # 3 EXISTING. TEST OK | |
| 03/14/2005 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 03/11/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* VACUUM TEST M-H # 3 TEST OK 28?? VACUUM TEST M-H #2-TEST OK 20?. VACUUM TEST M-H #1 TEST OK 25?? | |
| 03/08/2005 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* INSP ON SITE SEWER AS PER LETTER OF AGREEMENT JAN 3/05 AGREED TO BY DAVE MANN- BUILDING OFFICIAL & GREGOR& GRENIER ENGINEERING. MARCH 8/05 LOW PRESSURE AIR TEST FROM M-H #1 TO M-H #3 8" SDR-35 NOT READY WILL REQUIRE ?? OF GRADE-VACUUM TEST ON MANHOLES-MAIN?? |