Permit: T04PL02062

Parcel: 138230840


Addresses:

758 W CALLE ARAGON

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
02/07/2005 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :* ALL CORRECTIONS HAVE BEEN MADE
01/21/2005 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :* 1) SHALL CONNECT WATER HTR FLU VENT TO APPLIANCE COLLAR AND TO FLU VENT THRU ROOF. WITH ( 3) SHEET METAL SCREWS PER JOINT. 2) SHALL REPLACE WATER HTR SHUT OFF VALVE WITH NEW AGA OR CSA SHUT OFF VALVE. 3) SHALL CAP OFF GAS SUPPLY TO RANGE AND TO FUTURE FURNACE. 4) SHALL EXTEND T & P DRAIN WITH 3/4" PIPE MIN TO DAYLIGHT AND TERMINATE WITH NO THREADS @ END OF PIPE. 5) GAS PRESSURE TEST IS OK UP TO WATER HTR RM. 6) OK TO BACKFILL TRENCH.