Permit: T04PL02060

Parcel: 135051690


Addresses:

6608 E CALLE LUNA

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/06/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/ 1) 10 PSI MINIMUM TEST ON ENTIRE GAS SYSTEM AT TIME OF INSPECTION
2) INSTALL UNDERGROUND PIPING ON FIRM BEDDING
3) VENT FROM WATER HEATER AND FURNACE TO BE 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' AND BE DBL WALL VENT PIPE WITH APPROVED CAP
3) PROVIDE AGA OR CSA APPROVED GAS VALVE AT ALL APPLIANCES
4) RIDGID PIPE TO PENETRATE APPLIANCE HOUSING AT FURNACE
5) PROVIDE BONDING OF BLDG GAS PIPING
12/06/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/17 PSI AIR TEST FROM METER SCOTCH COAT UNDERGROUND TO BUILDING SERVING ENTRY THRU VALVE TO EXISTING PIPING TO WATER HEATER, FURNACE & STOPVE APPROVED
11/24/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/3:00PM PLEASE HAVE SOMEONE PRESENT ON DAY OF REINSPECTION TO PROVIDE ACCESS TO GAS SYSTEM
11/22/2004 PLUMBING - GAS PRESSURE TEST Cancelled PER RICKY 730-7835
11/22/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*