Permit: T04PL02031

Parcel: 130170330


Addresses:

4002 E 27TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/23/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
11/22/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
11/19/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)TIE PIPING IN FROM YARD TO BUILDING AND 10 PSI MINIMUM TEST ENTIRE SYSTEM 2)INSTALL APPROVED AGA OR CSA GAS VALVES AT ALL APPLIANCES 3)WHERE UNIONS ARE NECESSARY USE LEFT-RIGHT NIPPLE & COUPLINGS 4)RIDGID PIPE THRU APPLIANCE HOUSING AT FURNACE 5)WATER HEATER TEMPERATURE & PRESSURE DRAIN TO TERMINATE 6"-24" FROM FINISH FLOOR