Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/05/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/18/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/1)PROVIDE PROPER INSTALLATION OF PETITION OF APPEAL FOR WATER HEATER T&P 2)SIAL PENITRATIONS INTO BUILDING FROM GAS PIPING. | |
| 11/16/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)PROVIDE BONDING OF BUILDING GAS PIPING 2)SINGLE WALL VENTS FROM WATER HEATER & FURNACE REQUIRE 6" CLEARANCE FROM COMBUSTABLES IN CLOSET. 3)PROVIDE LOWER COMBUSTION AIR FOR WATER HEATER & FURNACE CLOSET OF 100 SQ INCHES MINIMUM 4)WATER HEATER TEMPERATURE & PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL SIGNED BY CITY ON SITE WITH APPROVED INSTALLATION |