Permit: T04PL02016

Parcel: 107112770

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04PL02016

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/17/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
11/16/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 10 PSI AIR TEST FROM METER BEHIND UNIT C SCOTCH COAT UNDERGROUND UP TO ROOF TOP OVER TO UNIT E TO WATER HEATER AND FURNACE ONLY OK
2) WATER HEATER TO BE PERMITTED THRU CITY
3) WATER HEATER T & P DRAIN TO GRAVITY DRAIN TO DAYLIGHT
4) PROVIDE DIELECTRIC CONNECTION TO WATER HEATER
FOR BOTH HOT AND COLD WATER CONNECTIONS
5) PROVIDE MINIMUM 1" CLEARANCE FROM COMBUSTIBLES ON DBL WALL VENT FROM FURNACE THRU CEILING