Inspection History: PLUMBING - FINAL
Permit Number - T04PL02016
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/17/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
11/16/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 10 PSI AIR TEST FROM METER BEHIND UNIT C SCOTCH COAT UNDERGROUND UP TO ROOF TOP OVER TO UNIT E TO WATER HEATER AND FURNACE ONLY OK 2) WATER HEATER TO BE PERMITTED THRU CITY 3) WATER HEATER T & P DRAIN TO GRAVITY DRAIN TO DAYLIGHT 4) PROVIDE DIELECTRIC CONNECTION TO WATER HEATER FOR BOTH HOT AND COLD WATER CONNECTIONS 5) PROVIDE MINIMUM 1" CLEARANCE FROM COMBUSTIBLES ON DBL WALL VENT FROM FURNACE THRU CEILING |