Permit: T04PL01968

Parcel: 136121030


Addresses:

3241 S PORTIA AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/08/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
11/04/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)PROVIDE AGA OR CSA APPROVED VALVES AT ALL APPLIANCES 2)PROVIDE BONDING OF BUILDING GAS PIPING 3)WATER HEATER TEMPERATURE & PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT OR PROVIDE PETITION OF APPEAL SIGNED BY CITY ON SITE WITH APPROVED INSTALLATION. OK TO COVER UNDERGROUND PIPING. 15 PSI TEST FROM METER NEW PE UNDERGROUND TO HOUSE SERVICE ENTRY EXISTING TO WATER HEATER, ROOF TOP UNIT. RETEST WITH APP. VALVES