Permit: T04PL01960

Parcel: 117062100


Addresses:

128 S HERBERT AV


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T04PL01960

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
11/09/2004 PLUMBING - GAS PRESSURE TEST Approved
11/08/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL OBTAIN APPEALL FORM FROM OUR OFFICE APPROVING ALTERNET METHOD OF T&P TERMINATION PRIOR TO INSPECTION 2)SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON WATER HTR FLU VENTS AND @ APPLIANCE COLLAR 3)SHALL STRAP DOWN GAS SUPPLY TO DELETED WALL FURNACE IN UNIT #3
11/04/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)GAS PRESSURE GAGE IS @ 0 LBS. 10 LBS MIN. 2)SHALL REMOVE UNIONS IN LINE AND REPLACE WITH RIGHT & LEFT HAND NIPPLE 3)I HAVE TO HAVE ACCESS TO ALL GAS APPLIANCES INSIDE DWELLING 4)HAVE PLBG CONTRACTOR CHECK INTIRE SYSTEM FOR CODE VIOLATIONS.