Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/23/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/23/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK 2)GAS SHUT OFF VALVES OK 3)WATER HTR FLU VENT, T&P VALVE OK 4)ALL CORRECTIONS HAVE BEEN MADE | |
| 11/19/2004 | PLUMBING - FINAL | Cancelled | ||
| 11/19/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) CANCELLED BY INSTALLER | |
| 11/18/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SEE NOTE #2 AS REQUESTED AND NOTE #3 & 4 2)SHALL PROVIDE 1-10X10 LOUVER GRILL LOCATED 12" BELOW CEILING ON DOOR 3)SHALL EXTEND DBL WALL FLU VENT BELOW CEILING THEN CONNECT SINGLE WALL FLU VENT CONNECTOR 4)RE TEST SYSTEM |
|
| 11/09/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL APPLY TAPE PRIMER TO ALL UNDERGROUND FITTINGS THEN APPLY 10-MIL TAPE AROUND ENTIRE FITTING AND @ WRENCH MARKS ON PIPE. 2)CAN NOT HAVE ANY UNIONS IN LINE. USE RIGHT & LEFT HAND NIPPLE WHERE UNIONS ARE NECESSARY 3)WATER HTR FLU VENT SHALL HAVE (3) SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR. 4)SHALL APPLY FOR APPEAL FORM @ OUR OFFICE FOR ALTERNATE METHOD OF T&P DRAIN INSTALLATION. THIS DRAIN CAN NOT HAVE ANY TEAPED WATER OR GO UP THRU ROOF. 5)PROVIDE 10 LBS AIR TEST @ TIME OF INSPECTION |
|
| 11/02/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/NO ONE HOME! THERE MUST BE AN ADULT PRESENT @ TIME OF INSPECTION |