Permit: T04PL01943

Parcel: 120081730


Addresses:

105 W ILLINOIS ST

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/23/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/23/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK 2)GAS SHUT OFF VALVES OK 3)WATER HTR FLU VENT, T&P VALVE OK 4)ALL CORRECTIONS HAVE BEEN MADE
11/19/2004 PLUMBING - FINAL Cancelled
11/19/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) CANCELLED BY INSTALLER
11/18/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SEE NOTE #2 AS REQUESTED AND NOTE #3 & 4 2)SHALL PROVIDE 1-10X10 LOUVER GRILL LOCATED 12" BELOW CEILING ON DOOR 3)SHALL EXTEND DBL WALL FLU VENT BELOW CEILING THEN CONNECT SINGLE WALL FLU VENT CONNECTOR 4)RE TEST SYSTEM
11/09/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)SHALL APPLY TAPE PRIMER TO ALL UNDERGROUND FITTINGS THEN APPLY 10-MIL TAPE AROUND ENTIRE FITTING AND @ WRENCH MARKS ON PIPE. 2)CAN NOT HAVE ANY UNIONS IN LINE. USE RIGHT & LEFT HAND NIPPLE WHERE UNIONS ARE NECESSARY 3)WATER HTR FLU VENT SHALL HAVE (3) SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR. 4)SHALL APPLY FOR APPEAL FORM @ OUR OFFICE FOR ALTERNATE METHOD OF T&P DRAIN INSTALLATION. THIS DRAIN CAN NOT HAVE ANY TEAPED WATER OR GO UP THRU ROOF. 5)PROVIDE 10 LBS AIR TEST @ TIME OF INSPECTION
11/02/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/NO ONE HOME! THERE MUST BE AN ADULT PRESENT @ TIME OF INSPECTION