Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04PL01914
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/17/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK 2)GAS SHUT OFF VALVES OK 3)GAS WATER HTR OK 4)GAS PACK ON ROOF OK | |
| 11/15/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*/1WHERE UNIONS ARE NECESSARY LEFT-RIGHT NIPPLES & COUPLINGS SHALL BE USED 2)SINGLE WALL VENT FROM WATER HEATER REQUIRES 6" CLEARANCE FROM COMBUSTABLES 3)ALL ABOVE GRADE GAS PIPING TO BE 6" MINIMUM ABOVE GRADE. 4)ALL UNDERGROUND GAS PIPING TO BE 12" MINIMUM COVER. | |
| 11/05/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |