Permit: T04PL01878

Parcel: 107130680


Addresses:

2703 N STONE AV #02

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/25/2004 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*/20 PSI AIR TEST FROM METER TO WATER HEATER & STOVE OK.
03090-NOT READY 1)PROVIDE BONDING OF BUILDING GAS PIPING. 2)SECURE WATER HEATER T&P DRAIN AND TERMINATE WITH 90 DEGREES DOWN. 3)SECURE GAS PIPING CORRECTLY WITH APPROVED MATERALS? AT CORRECT INTERVALS
10/19/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
There is no access to the site.| 920*/ 1) NO PERSON ON SITE 2) NO ACCESS TO INSIDE OF HOUSE 3) WATER HEATER B-1 VENT NEEDS TO BE RUN TO BENEATH CEILING JOIST 4) CLEARANCE SINGEL WALL CONNECTOR PIPE TO COMBUSTIBLES, 8" 5) APPLIANCES INSIDE OF HOUSE ??, NO ACCESS