Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/25/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :*/20 PSI AIR TEST FROM METER TO WATER HEATER & STOVE OK. 03090-NOT READY 1)PROVIDE BONDING OF BUILDING GAS PIPING. 2)SECURE WATER HEATER T&P DRAIN AND TERMINATE WITH 90 DEGREES DOWN. 3)SECURE GAS PIPING CORRECTLY WITH APPROVED MATERALS? AT CORRECT INTERVALS |
|
| 10/19/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : There is no access to the site.| 920*/ 1) NO PERSON ON SITE 2) NO ACCESS TO INSIDE OF HOUSE 3) WATER HEATER B-1 VENT NEEDS TO BE RUN TO BENEATH CEILING JOIST 4) CLEARANCE SINGEL WALL CONNECTOR PIPE TO COMBUSTIBLES, 8" 5) APPLIANCES INSIDE OF HOUSE ??, NO ACCESS |