Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/12/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/09/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/PLEASE READ NOTES FROM 10/07/04 INSPECTION AND FOLLOW ALL OF THEM |
|
| 10/07/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/REMOVE TAPE FROM VENT CONNECTOR ON WATER HEATER VENT-NEED TO SEE CONNECTIONS. EXTEND T&P DRAIN LINE INTO DRAIN PAN. PLUG OUTLET ON DRAIN PAN. PROVIDE A 125 PSI PESSURE RELIEF OUTSIDE ON WATER PIPE & PROVIDE A PETITION OF APPEAL FOR ALTERNATE METHOD OF RUNNING THE T&P DRAIN LINE & LEAVE ON SITE. PROVIDE HIGH & LOW COMBUSTION AIR VENTS TO WATER HEATER & FURNACE ENCLOSURE. |
|
| 10/05/2004 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/PLEASE SCHEDULE AN INSPECTION WHEN AN ADULT WILL BE PRESENT |