Permit: T04PL01792

Parcel: 121121860


Addresses:

5447 E BELLEVUE ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T04PL01792

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/12/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/ALL CORRECTIONS HAVE BEEN MADE. LEFT GAS CARD
10/06/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/14 PSI TEST. 1)EXTEND T&P DRAIN TO DAYLIGHT 6" ABOVE GRADE. PROVIDE MIN. 1" CLEARANCE AROUND WATER HEATER VENT. PROVIDE MIN. 3 SCREWS IN JOINTS OF VENT CONNECTORS. PROVIDE AN APPROVED CAP ON WATER HEATER VENT. 2)EXTEND FURANCE VENT 2' ABOVE EVAP. COOLER. 3)USE AMERI VENT. 4)NEED ACCESS TO INSIEDE HOUSE 5)GAS PRESSURE TEST IS OK RECALL FOR INSPECTION