Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/13/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*PRESSURE TEST OK PIPING OK TO COVER OK FOR GAS |
| 12/06/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) YOU CALLED ME. WE AGREED 2:00 PM-I ARRIVED 2:15 PM NOBODY HOME |
| 10/11/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/1)A THREAD PROTECTOR IS NOT AN APPROVED GAS FITTING USE STD. TAPER THREAD COUPOLING 2)ALL FITTINGS AND MARRED PIPE TO BE PRIMED AND TAPED. 3)MAKE ALL CONNECTIONS - TEST ENTIRE SYSTEM 4)GAS PIPE TO BE AT LEAST 12" DEEP. 5)ALL VALVES TO BE AGA OR GSA APPROVED |