Permit: T04PL01767

Parcel: 106070940


Addresses:

1249 W NAVAJO ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/13/2004 PLUMBING - FINAL Approved IVRS - Inspection :*PRESSURE TEST OK PIPING OK TO COVER OK FOR GAS
12/06/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) YOU CALLED ME. WE AGREED 2:00 PM-I ARRIVED 2:15 PM NOBODY HOME
10/11/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)A THREAD PROTECTOR IS NOT AN APPROVED GAS FITTING USE STD. TAPER THREAD COUPOLING 2)ALL FITTINGS AND MARRED PIPE TO BE PRIMED AND TAPED. 3)MAKE ALL CONNECTIONS - TEST ENTIRE SYSTEM 4)GAS PIPE TO BE AT LEAST 12" DEEP. 5)ALL VALVES TO BE AGA OR GSA APPROVED