Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/27/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*/11 PSI AIR TEST FROM METER NEW 3/4" SCOTCH COAT TO BUILDING SERVICE UNITS, TO STOVE, FURANCE AND WATER HEATER OK. CORRECTION MADE. GAS CARD AT METER 889-1888 |
| 09/24/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/1)PROVIDE BONDING OF BUILDING GAS PIPING. 2)VENT FROM WATER HEATER WHEN WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE COOLER AND HAVE APPROVED VENT CAP 3)ALL APPLIANCES TO HAVE AGA OR CSA APPROVED VALVES. INSTALL VALVES & RETEST SYSTEM 4)WATER HEATER T&P DRAIN TO TERMINATE AT 90 DEGREES DOWN |