Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04PL01707

Parcel: 128030630


Addresses:

5731 E SCARLETT ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/24/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/CORRECTION MADE
09/23/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)PROVIDE COPIES OF IN HOUSE BACKFLOW CERTIFICATION 2)LEAK AT P-4 SINK T BE CORRECTED. 3)CONNECT ALL EQUIPMENT. WHAT IS UNCONNECTED BACKFLOW DEVICE GOING TO SUPPLY?
09/22/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)15 PSI AIR TEST FROM METER TO WATER HEATER, STOVE, AND ROOF TOP UNIT OK. 2)WATER HEATER TEMPORATURE & PRESSURE RELIEF IS LEAKING AND SHALL BE REPLACED AND GRAVITY DRAIN TO DAYLIGHT
09/17/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* INSPECTION CANCELLED