Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/26/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 09/29/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/13 PSI AIR TEST FROM METER NEW 1 1/4 SCOTCH COAT UNDERGROUND UP AT BUILDING OVERHEAD TO DRYER, STOVE, WATER HEATER, AND FURANCE OK. 1)HAVE NEW WATER HEATER ADDED TO YOUR PERMIT. 2)PLEASE COMPLY WITH ITEMS NOTED ON 9/20/04 INSPECTION. |
| 09/20/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/1)ALL GAS APPLIANCES TO HAVE AGA OR CSA APPROVED GAS SHUT OFF VALVES 2)INSTALL YOUR BONDING FOR BUILDING GAS PIPING 3)VENT FROM WATER HEATER & FURANCE TO BE 3' ABOVE COOLER WITON? WITHIN 10' OF COOLER INTAKE 4)PROVIDE ROOF FLASHING AT ALL ROOF PENATRATIONS 5)REPAIR AND RETEST SYSTEM 6)WATER HEATER T&P TO GRAVITY DRAIN TO DAYLIGHT |