Permit: T04PL01671

Parcel: 134244080


Addresses:

6633 E 17TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/26/2004 PLUMBING - FINAL Approved IVRS - Inspection :*
09/29/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/13 PSI AIR TEST FROM METER NEW 1 1/4 SCOTCH COAT UNDERGROUND UP AT BUILDING OVERHEAD TO DRYER, STOVE, WATER HEATER, AND FURANCE OK. 1)HAVE NEW WATER HEATER ADDED TO YOUR PERMIT. 2)PLEASE COMPLY WITH ITEMS NOTED ON 9/20/04 INSPECTION.
09/20/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*/1)ALL GAS APPLIANCES TO HAVE AGA OR CSA APPROVED GAS SHUT OFF VALVES 2)INSTALL YOUR BONDING FOR BUILDING GAS PIPING 3)VENT FROM WATER HEATER & FURANCE TO BE 3' ABOVE COOLER WITON? WITHIN 10' OF COOLER INTAKE 4)PROVIDE ROOF FLASHING AT ALL ROOF PENATRATIONS 5)REPAIR AND RETEST SYSTEM 6)WATER HEATER T&P TO GRAVITY DRAIN TO DAYLIGHT