Date Description Inspector Results Comments
11/03/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/FROM EXISTING 1 1/2 UNDERGROUND UP OVER WALK WAY COVER DOWN UNDERGROUND TO EXISTING BUILDING SERVICE ENTRANCE TO WATER HEATER UP TO (2) ROOF TOP UNITS 15 PSI AIR TEST OK. NO GAS CARD REQUIRED
10/14/2004 PLUMBING - FINAL Not ready for Inspection WATER HEATER T&P TO GRAVITY DRAIN TO DAYLIGHT 2) WATER HEATER TO HAVE UPPER AND LOWER COMBUSTION AIR INTAKES 3) GAS PIPING CANNOT PASS UNDER GROUND AT PORCH 4) APPLIANCE VALVE TO BE WITHIN 4' OF APPLIANCES