Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04PL01633
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/26/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) PHASE TWO COMPLETE 2) ENGINEERING SENT TO PDEQ 3) PLUMBING FINAL PHASE ONE AND PHASE TWO APPROVED |
|
05/24/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) DOOR LOCKED-NO ACCESS |
|
01/19/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* AIR TEST BETWEEN MH #6 & #7 1) #5 AIR TEST BETWEEN MH #6 & #7 OK. 5# AIR TEST BETWEEN #6 & 5 OK 5# AIR TEST BETWEEN #4 & #5 OK. 5# AIR TEST BETWEEN #4 & #3 OK | |
11/24/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/1)JARED JEWELERS SEWER IS TEMPORARY OUT TO LIMBERLOST - OK TO USE 2)PRIVATE SEWER PROJECT ON HOLD | |
11/15/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/1)TEMPORARY SDR35 SEWER TO NEXT CLEAN-OUT OK. AIR TEST ON EVERYTHING THATS BEEN INSTALLED SO FAR. NEED TO SEE SECTION BETWEEN LAST CLEAN-OUT AND HCS | |
11/10/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/VISUAL INSPECTION OF 4" SDR 35 PAD 3 SEWER FROM 2-WAY CLEANOUT TO NEW C.O. #2. 1)PROVIDE VERIFICATION OF GRADE AND AIR TEST OF THIS AT LATER DATE TO COVER THIS POINT |
|
10/12/2004 | PLUMBING - ROUGH, SOIL | Cancelled | PER CONTRACTOR | |
10/12/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
10/05/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* MANHOLE EASES # 6 & # 7 ??. 6" SPR 35 EXTENDS 40' EAST OF M.H. #7 4"SDR 35 BRANCH FOR JEWELRY STORE OK TO WITHIN 12: OF ? CLEAN OUT. JUST NORTH OF M.H #5 -4"SDR 35 REPLACED WITH 6"SDR 35. JUST WEST OF M.H #3 -#6 SDR 35 INSTALLED 40' ON BRANCH. OK TO COVER ALL AREAS, SUBJECT TO AIR TEST AND VERIFICATION OF GRADE. | |
09/30/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) SDR 35 BETWEEN MANHOLE #4, #5 OK TO COVER AND (#5, 6) SUBJECT TO AIR TEST AND VERIFICATION OF GRADE. 2) MANHOLE BASES # 3, 4, 5, OK. 3) SDR 35 BETWEEN MANHOLES #5, #6 AND #6 & #7 OK SUBJECT TO TEST AND GRADE. | |
09/28/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/SDR 35 BETWEEN MANHOLE #2 & #3 AND #3 & #4 OK TO COVER-SUBJECT TO AIR TEST AND VERIFICATION OF GRADE |